Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute,150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Sung Tack Hong
HANARO Management Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Gee-Yang Han
HANARO Management Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Ke Chon Choi
Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute,150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Jei-Won Yeon
Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute,150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Hung-Woo Kim
Nuclear Chemistry Research Division, Korea Atomic Energy Research Institute,150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Man-Soon Cho
Neutron Utilization Technology Development Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Kyung-Duk Jang
Radioisotope Utilization Technology Development Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Ul Jae Park
Radioisotope Utilization Technology Development Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Sang-Jun Park
Neutron Utilization Technology Development Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Hoan-Sung Jung
HANARO Management Division, Korea Atomic Energy Research Institute, 150 Deokjin-dong, Yuseong-gu, Daejeon 305-353, Republic of Korea
Corresponding Author(s) : Hee-Jung Im
imhj@kaeri.re.kr
Asian Journal of Chemistry,
Vol. 25 No. 12 (2013): Vol 25 Issue 12
Interpretation of coolant chemistry performance is very important because the performance can be an effective indicator in monitoring operational safety of nuclear power plants. To determine the radiolysis degree of boric acid solutions, which are added for neutron absorption to control core reactivity during the nuclear power plant operation, and understand the physico-chemical nature of the process under neutron irradiation in a nuclear reactor, the preparation and safety check points for the irradiation of boric acid solutions are discussed.
Im, H.-J., Tack Hong, S., Han, G.-Y., Chon Choi, K., Yeon, J.-W., Kim, H.-W., … Jung, H.-S. (2013). Pre-Irradiation of Boric Acid Solutions in a Research Reactor. Asian Journal of Chemistry, 25(12), 7013–7015. https://doi.org/10.14233/ajchem.2013.06