A rapid and sensitive HPLC method was developed for the estimation of rapril in pharmaceutical dosage forms. Rapril was chromatographed on a reverse phase C18 column, mobile phase consisting of 0.05 M KH2PO4, acetonitrile and methanol in the ratio of 40 : 40 : 20. The mobile phase was pumped at a flow rate of 1.0 mL/n and the eluent was monitored at 216 nm. The calibration curve was linear in the range of 0.5–50 μg/mL. The results of the study show that the present HPLC method is simple, precise, specific, less time consung and accurate for the estimation of rapril in pharmaceutical dosage forms.
Keywords
RaprilDosage formsReverse-phase HPLC
Full Article